Monday, 1 August 2016

Bearing Protector to solve bearing premature failure

Mechanical seal type centrifigul pump, oftenly encounter bearing premature failure due to lubricant oil contaminate with water, where this water come from steam quenching for mechanical seal,  where the steam condensate travel through pump shaft entering the oil seal of oil compartment.


To solve this issue, a bearing protector is recommended to install. 
Ideally dual face bearing protectors, offering double the protection of a conventional single seal face design.